Heart pacemaker - discharge

Cardiac pacemaker implantation - discharge; Artificial pacemaker - discharge; Permanent pacemaker - discharge; Internal pacemaker - discharge; Cardiac resynchronization therapy - discharge; CRT - discharge; Biventricular pacemaker - discharge; Heart block - pacemaker discharge; AV block - pacemaker discharge; Heart failure - pacemaker discharge; Bradycardia - pacemaker discharge

A pacemaker is a small, battery-operated device that senses when your heart is beating irregularly or too slowly. It sends a signal to your heart that makes your heart beat at the correct pace. This article discusses what you need to do to take care of yourself when you leave the hospital.

Note: Care of certain specialized pacemakers or pacemakers combined with defibrillators may be different than described below.

When You're in the Hospital

You had a pacemaker placed in your chest to help your heart beat properly.

  • A small cut was made on your chest below your collarbone. The pacemaker generator was then placed under the skin at this location.
  • Leads (wires) were connected to the pacemaker, and one end of the wires was threaded through a vein into your heart. The skin over the area where the pacemaker was placed was closed with stitches.

Most pacemakers have only one or two wires that go to the heart. These wires stimulate one or more of the chambers of the heart to squeeze (contract) when the heartbeat gets too slow. A special type of pacemaker can be used for people with heart failure. It has three leads to help the heart beat in a more coordinated manner.

Some pacemakers also can deliver electric shocks to the heart that can stop life-threatening arrhythmias (irregular heartbeats). These are called "cardioverter defibrillators."

A newer type of device called a "leadless pacemaker" is a self-contained pacing unit that is inserted into the right ventricle of the heart. It does not need connecting wires to a generator under the skin of the chest. It is guided into place via a catheter inserted in a vein in the groin. Currently, leadless pacemakers are available only for people who have certain medical conditions involving a slow heartbeat.

You should know what type of pacemaker you have and which company made it.

What to Expect at Home

You will be given a card to keep in your wallet.

  • The card has information about your pacemaker and includes the name and telephone number of your doctor (cardiologist). It also tells others what to do in case of an emergency.
  • You should always carry this wallet card with you. It will be helpful to any health care provider that you may see in the future because it says what kind of pacemaker you have.

You should wear a medic alert bracelet or necklace that says you have a pacemaker. In a medical emergency, health care workers taking care of you should know you have a pacemaker.

Be Careful Around Things With Magnets

Most machines and devices will not interfere with your pacemaker. But some with strong magnetic fields may. Always ask your provider about any specific device that you need to avoid. Do not put a magnet near your pacemaker.

Most appliances in your home are safe to be around. This includes your refrigerator, washer, dryer, toaster, blender, computers and fax machines, hair dryer, stove, CD player, remote controls, and microwaves.

You should keep several devices at least 12 inches (30 centimeters) away from the site where the pacemaker is placed under your skin. These include:

  • Battery powered cordless tools (such as screwdrivers and drills)
  • Plug-in power tools (such as drills and table saws)
  • Electric lawnmowers and leaf blowers
  • Slot machines
  • Stereo speakers

Tell all providers that you have a pacemaker before any tests are done.

Some medical equipment may interfere with your pacemaker.

Stay away from large motors, generators, and equipment. Do not lean over the open hood of a car that is running. Also stay away from:

  • Radio transmitters and high-voltage power lines
  • Products that use magnetic therapy, such as some mattresses, pillows, and massagers
  • Large electrical- or gasoline-powered appliances

If you have a cell phone:

  • Do not put it in a pocket on the same side of your body as your pacemaker.
  • When using your cell phone, hold it to your ear on the opposite side of your body.

Be careful around metal detectors and security wands.

  • Handheld security wands may interfere with your pacemaker. Show your wallet card and ask to be hand searched.
  • Most security gates at airports and stores are OK. But do not stand near these devices for long periods. Your pacemaker may set off alarms.

After any operation, have your provider check your pacemaker.

Wound Care

You should be able to do normal activities in 3 to 4 days.

For 2 to 3 weeks, do not do these things with the arm on the side of your body where the pacemaker was placed:

  • Lifting anything heavier than 10 to 15 pounds (4.5 to 7 kilograms)
  • Too much pushing, pulling, or twisting

Do not lift this arm above your shoulder for several weeks. Do not wear clothes that rub on the wound for 2 or 3 weeks. Keep your incision completely dry for 4 to 5 days. Afterward, you may take a shower and then pat it dry. Always wash your hands before touching the wound.

Follow-up

Your cardiologist will tell you how often you will need to have your pacemaker checked. In most cases, it will be every 6 months to a year. The exam will take about 15 to 30 minutes.

The batteries in your pacemaker should last 6 to 15 years. Regular checkups can detect if the battery is wearing down or if there are any problems with the leads (wires). Your cardiologist will change both the generator and battery when the battery gets low.

When to Call the Doctor

Contact your cardiologist if:

  • Your wound looks infected (redness, increased drainage, swelling, pain).
  • You are having the symptoms you had before the pacemaker was implanted.
  • You feel dizzy or short of breath.
  • You have chest pain.
  • You have hiccups that do not go away.
  • You were unconscious for a moment.

References

American College of Cardiology website. The leadless pacemaker. www.acc.org/latest-in-cardiology/ten-points-to-remember/2019/06/10/13/49/the-leadless-pacemaker. Updated June 10, 2019. Accessed July 29, 2024.

Chung MK, Daubert JP. Pacemakers and implantable cardioverter-defibrillators. In: Libby P, Bonow RO, Mann DL, Tomaselli GF, Bhatt DL, Solomon SD, eds. Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine. 12th ed. Philadelphia, PA: Elsevier; 2022:chap 69.

Chung MK, Patton KK, Lau CP, et al. 2023 HRS/APHRS/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure. Heart Rhythm. 2023;20(9):e17-e91. PMID: 37283271 pubmed.ncbi.nlm.nih.gov/37283271/.

Glikson M, Nielsen JC, Kronborg MB, et al. ESC Scientific Document Group. 2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: developed by the Task Force on cardiac pacing and cardiac resynchronization therapy of the European Society of Cardiology (ESC) with the special contribution of the European Heart Rhythm Association (EHRA). European Heart Journal. 2021;42(35):3427–3520. PMID: 35525571 pubmed.ncbi.nlm.nih.gov/35525571/.

Santucci PA, Wilber DJ. Electrophysiologic procedures and surgery. In: Goldman L, Cooney KA, eds. Goldman-Cecil Medicine. 27th ed. Philadelphia, PA: Elsevier; 2024:chap 54.

Review Date: 7/14/2024

Reviewed By: Michael A. Chen, MD, PhD, Associate Professor of Medicine, Division of Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed by David C. Dugdale, MD, Medical Director, Brenda Conaway, Editorial Director, and the A.D.A.M. Editorial team.

The information provided herein should not be used during any medical emergency or for the diagnosis or treatment of any medical condition. A licensed medical professional should be consulted for diagnosis and treatment of any and all medical conditions. Links to other sites are provided for information only -- they do not constitute endorsements of those other sites. No warranty of any kind, either expressed or implied, is made as to the accuracy, reliability, timeliness, or correctness of any translations made by a third-party service of the information provided herein into any other language. © 1997- A.D.A.M., a business unit of Ebix, Inc. Any duplication or distribution of the information contained herein is strictly prohibited.